BlazeCut Vehicle Fire Suppression System

The System Operation:   Designed to protect small enclosed spaces with greater risks of fire. Simple and easy to install, the BlazeCut T Series system operates automatically without any external power source. The extinguishing agent is stored in a tube, which also serves to apply extinguishing agent directly to the fire at its source. When a fire occurs, the combination of heat and internal pressure causes the tube to rupture, creating a nozzle, releasing the extinguishing agent. The T Series system consists of a heat sensitive BlazeCut Tube made of specialized plastic which is closed by a stainless steel fittings on each end. The BlazeCut Tube has both storage and detection function which means that the extinguishing agent is stored directly in the BlazeCut Tube and no additional storage device such as cylinder is needed.
  • Compact; small footprint of the BlazeCut Tube with A, B, C and electrical fires class rating can protect almost any space
  • No cylinder for storage required; the whole system can be placed inside the protected enclosure as there is no cylinder
  • Cost-effective; long working life, automatic activation, zero maintenance beats the competition in cost-effectiveness
  • Optional pressure switch; and other additional components like signaling unit to perform further safety functions
  • Clean and effective extinguishing agent; world-wide known and accepted HFC gas (HFC-227ea) fire agent
  • No pressurization needed; the system works by increasing pressure of the extinguishing agent when heated
  • Automatic operation; based on increased temperature: ideal for non-occupied spaces
  • Fully independent; TxxxE system is operational 24/7 without any power supply
  • Maintenance free; during entire working life means zero maintenance costs
  • Long working life; up to 10 years depending on the type of application
  • No harm; to protected enclosure when system discharged
  • Simple installation; system easily secured by cable ties or clamps
  • Pressure gauge; to monitor the system pressure at any time
  • Minimum operation temperatures; down to -40°C (-40°F)
  • Maximum operation temperature; up to 90°C (194°F)

Applications can be calculated by a simple process, measure the sealed enclosures Width x Height x Depth in metres or feet
and this will calculate your required volume in m3
or ft3
. Then refer to the chart below for the maximum volume protected for
electrical or engine applications to select the suitable T Series model.
Note: the enclosure should be enclosed or have minimal ventilation. The T Series system is not suitable for open areas. For
vehicle applications please refer to our application guide that can be found online at www.BlazeCut.com

Model* Maximum Volume Electrical Fires** @ 20°C (68°F) Maximum Volume Engine Fires** @ 20°C (68°F) Amount of Agent System Length Operation Temperature Activation Temperature
T025E 0.09 m3
3.18 ft3
0.09 m3
3.18 ft3
0.05 kg ± 2 g
0.11 lb ± 0.07 oz
28 cm
11.02 in
T050E 0.18 m3
6.36 ft3
0.14 m3
4.94 ft3
0.10 kg ± 2 g
0.22 lb ± 0.07 oz
53 cm
20.87 in
T100E 0.46 m3
16.24 ft3
0.35 m3
12.36 ft3
0.25 kg ± 5 g 113 cm
0.55 lb ± 0.17 oz
113 cm
44.48 in
T200E 0.91 m3
32.14 ft3
0.69 m3
24.37 ft3
0.50 kg ± 5 g
1.10 lb ± 0.17 oz
215 cm
84.64 in
-40°C to +90°C
-40°F to 194°F
105°C ± 3°C
221°F ± 5°F
T300E 1.37 m3
48.38 ft3
1.04 m3
36.73 ft3
0.75 kg ± 10 g
1.65 lb ± 0.35 oz
319 cm
125.59 in
T400E 1.82 m3
64.27 ft3
1.39 m3
49.09 ft3
3 1.00 kg ± 10 g
2.20 lb ± 0.35 oz
422 cm
166.14 in
T500E 2.28 m3
80.52 ft3
1.73 m3
61.09 ft3
1.25 kg ± 10 g
2.76 lb ± 0.35 oz
526 cm
207.09 in
T600E 2.73 m3
96.41 ft3
2.08 m3
73.45 ft3
1.50 kg ± 10 g
3.31 lb ± 0.35 oz
630 cm
248.03 in
T025ES 0.09 m3
3.18 ft3
0.09 m3
3.18 ft3
0.05 kg ± 2 g
0.11 lb ± 0.07 oz
35 cm
13.78 in
T050ES 0.18 m3
6.36 ft3
0.14 m3
4.94 ft3
0.10 kg ± 2 g
0.22 lb ± 0.07 oz
60 cm
23.62 in
T100ES 0.46 m3
16.24 ft3
0.35 m3
12.36 ft3
0.25 kg ± 5 g
0.55 lb ± 0.17 oz
120 cm
47.24 in
T200ES 0.91 m3
32.14 ft3
0.69 m3
24.37 ft3
0.50 kg ± 5 g
1.10 lb ± 0.17 oz
222 cm
87.40 in
-20°C to +80°C
-4°F to 176°F
100°C ± 2°C
212°F ± 4°F
T300ES 1.37 m3
48.38 ft3
1.04 m3
36.73 ft3
0.75 kg ± 10 g
1.65 lb ± 0.35 oz
326 cm
128.34 in
T400ES 1.82 m3
64.27 ft3
1.39 m3
49.09 ft3
1.00 kg ± 10 g
2.20 lb ± 0.35 oz
429 cm
168.89 in
T500ES 2.28 m3
80.52 ft3
1.73 m3
61.09 ft3
1.25 kg ± 10 g
2.76 lb ± 0.35 oz
533 cm
209.84 in
T600ES 2.73 m3
96.41 ft3
2.08 m3
73.45 ft3
1.50 kg ± 10 g
3.31 lb ± 0.35 oz
637 cm
250.79 in