GLP220 1 Loop Addressable Fire Alarm Panel

GLP-220 Addressable fire alarm controller (linkage) is a linkage fire alarm controller. this product uses RISC embedded technology based on ARM platform and master-slave networking technology. Manly suitable for hotels. karaoke bars. computer rooms. power substation, libraries, banks. Warehouses, apartments and other large fire alarm linkage systems. The product meets the national CE standard. It can be equipped with optical smoke detector, temperature detector, manual call point. siren and strobe light, Input output module, relay module, bus short circuit isolator. fire display panel and other field components produced by our company.

The GLP-220 is designed to provide early warning fire detection, to quickly identify the location of fire and provide user definable text informing the occupants of the building of potential smoke spread. Simultaneously, the GLP-220 will alert and evacuate the occupants, and control all necessary auxiliary command such as elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects requirements configured though Command Builder Set-up.

Feature :

  • Using RISC embedded CPU technology based on ARM platform and real-time preemption multi-task embedded operating system, with low power consumption. fast processing speed.
  • Fast system response. reliable and stable operation.
  • 1 loop bus. Max. 1 x 220 alarm/tankage address points.
  • Using color English LCD display. display content is clear and intuitive. easy to operate.
  • Have strong field programming ability. support the cross linkage between each circuit and equipment. all kinds of English information annotation. bus control equipment and multi-line control equipment mutual linkage can be set by field programming. can also use PC or notebook way for field programming.
  • With black box function, it can store 3000 fire alarm history records. 3000 linkage history records. and 3000 other history records.
  • Display smoke I temperature output curve and data. can intuitively observe the field parameter data.
  • Two 12V/1.3AH batteries.
Working voltage AC220V (110- 242V) 50/60Hz
Bus loop output voltage DC21V modulating
Working temperature 0℃~+50℃
Relative humidity < 95% (40±2°C) (no condensation)
Capacity of main power supply 28.5V/3A
Linkage power output 28.5V/500MA
Backup battery 1.3AH/12V, 2 pcs
Max current output for 500mA
conventional siren 1 loop with 220 address points
Equipment capacity LCD display
Display mode 3000 fire alarm records, 3000 linkage records,
Storage capacity and 3000 other history records
Dimension L300*W90.5*H180 mm
Weight 3.5 Kg
Transmission distance RVS wire 12 <1000m
installation Standard cabinet construction
Execution standard CE