The GLP-440 compriseof a range of analogue addressable, microprocessor-based fire alarm control equipment to offer flexibility in both design and operation. The System is 2 loops maximum capacity of 440 points, to meet the full requirements of the project. The GLP-440 Intelligent Fire Alarm Control Panel is designed and manufactured to meet the requirement of BS EN54.

The GLP-440 is designed to provide early warning fire detection, to quickly identify the location of fire and provide user definable text informingthe occupants of the building of potential smoke spread. Simultaneously, the GLP-440 will alert and evacuate the occupants, and control all necessary auxiliary command such as elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects requirements configured though Command Builder Set-up.

Feature:

  • EN54 Standard
  • Using RISC embedded CPU technology based on ARM platform and real-time preemption multi-task embedded operating system, with low power consumption, fast processing speed, fast systemresponse, reliableand stable operation.
  • 2 loop bus, Max. 2*220 alarm/linkage address points.
  • 8 sets of programmable active control outputs.
  • Using color English LCD display, display content is clear and intuitive,easy to operate.
  • Have strong field programming ability, support the cross linkage between each circuit and equipment, allkinds of English information annotation, bus control equipment and multi-line control equipment mutual linkage can be set byfield programming, can also use PC or notebook way for field programming.
  • With black box function, it can store 3000 fire alarm history records, 3000 linkage history records, and 3000other history records.
    Display smoke/temperature output curve and data, can intuitively observe the field parameter data.
Supply Voltage: AC220 V(187~ 242V)-50/60Hz
Backup battery: 7AH/12V, 2 pcs
Bus loop output voltage: DC21V modulating
Capacity of main power supply: 27V/14A
Linkage power output: 27V/3A
Equipment capacity: 2 loops, each with 220 address points
Operating temperature: 0~ +50 ℃
Environment humidity: ≤95%(40±2℃) (no condensation)
Number of manual control disk 1
Number of manual direct control output: 8 sets
Display mode English color display
Storage capacity 3000 fire alarm records, 3000 linkage records, and 3000 other

history records

Dimension L400*W500*H115 mm
Transmission distance RVS wire 1² ≤1000m