Intelligent Fire Alarm Control Panel IFP-2100

The IFP-2100, IFP-2100HV, RFP-2100, and RFP-2100HV (red) and IFP-2100B, IFP 2100HVB, RFP-2100B, and RFP-2100HVB (black) are the latest intelligent addressable FACPs (Fire Alarm Control Panels) from Honeywell’s Farenhyt™ line and are direct replacements for the IFP-1000(HV), IFP-2000(HV), and RPS-2000(HV) FACPs. The RFP 2100(HV)(B) performs the same functions as the IFP-2100(HV)(B) but does not include a display. The FACPs have one built-in SLC (signaling line circuit), which can support 159 System Sensor® IDP/SK detectors and 159 IDP/SK modules, or 127 Hochiki® SD protocol devices. Additional SLC loops can be added for a maximum of 2100 (IDP/SK) or 2032 (SD) points per panel. The built-in digital alarm communicator/transmitter (DACT) is dual technology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available. The IFP-2100 has eight onboard Flexput® circuits that can be configured as notification outputs or auxiliary power. The IFP-2100 also has a form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. The IFP-2100 has interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. RFP-2100 panels can be used in a networked system where at least one IFP 2100 is in the system.
  • Complies with UL 864 10th Edition and UL
    2572 2nd Edition Standards
  • Expandable SLC loops to 2100 (IDP/SK) or
    2032 (SD) point capacity
  • Eight Flexput circuits for NAC outputs or
    auxiliary power
  • Selectable strobe synchronization for
    Amseco®, System Sensor, Wheelock®, and
    Gentex® devices
  • Built-in DACT with IP and optional cellular
    reporting
  • Built-in USB interface for quick and easy
    programming
  • JumpStart® auto programming reduces
    installation time
  • 999 software zones and 999 output groups
    for flexible design options
  • 23 preset notification cadence patterns
    (including ANSI® 3.41)
  • Allows up to 63 SBUS devices
  • Four programmable function keys
  • Two programmable relays and one fixed
    trouble relay
  • Compatible with SWIFT® wireless devices
  • Convenient field-upgradeable firmware
  • Network support for up to 32 sites
    product caption
  • Network card allows copper network
    connection with a multi-mode or single
    mode fiber connection
  • Real-time clock/calendar with automatic
    daylight savings control
  • History file with 1,000 event capacity
  • Available in a red or black cabinet
  • Surface mounting or flush mounting
    cabinet

SYSTEM CAPACITY

  • Intelligent Signaling Line Circuits: 1
    (expandable)
  • Addressable device capacity: 2100 (IDP/
    SK) or 2032 (SD)
  • Programmable software zones: 999
  • Output groups: 999
  • Output circuits: 8 (expandable)
  • SBUS devices: 63 (any combination)

ELECTRICAL

  • AC Power: 120 VAC, 60 Hz, 5A or 240VAC,
    50/60Hz, 2.8A
  • Standby Current: 230 mA
  • Alarm Current: 415 mA
  • Flexput Circuits: Terminal block provides
    connections for (eight Class B or four Class
    A) NACs or auxiliary power. Power-limited,
    supervised circuitry. Maximum current per
    circuit: 3 A. Cannot exceed 9A total for all
    circuits. End-of-line resistor: 4.7k ohm, ½
    watt for Class B NACs
  • Communication Loop: Supervised and
    power-limited, Class A or Class B, 32VDC,
    150mA
  • Two Programmable Relays and One Fixed
    Trouble Relay: Contact rating: 2.5 A @
    27.4 VDC (resistive), Form C
  • Battery: Cabinet holds maximum of two
    18AH batteries
  • Battery Charger Capacity: 17-55 AH

TEMPERATURE AND HUMIDITY RANGES

  • This system meets NFPA requirements for
    operation at 0 – 49°C (32– 120°F) and at a
    relative humidity 93% ± 2% RH (non
    condensing) at 32°C ± 2°C (90°F ± 3°F).
    However, the useful life of the system’s
    standby batteries and the electronic
    components may be adversely affected by
    extreme temperature ranges and humidity.
    Therefore, it is recommended that this
    system and its peripherals be installed in an
    environment with a normal room
    temperature of 15 – 27°C/60 – 80°F