An aerosol total flooding fire suppression system rapidly fills a protected area with a fire-suppressing agent (typically potassium-based) to extinguish or contain fires, offering a fast and effective solution for various fire hazards.
The system is designed for “total flooding,” meaning the agent is uniformly distributed throughout the enclosure to ensure effective suppression, even in hard-to-reach areas.
Advantages:
o Rapid Suppression: Aerosol systems are known for their fast activation and ability to quickly extinguish fires.
o Effective Coverage: The total flooding design ensures that the fire-suppressing agent reaches all areas of the protected space.
o Minimal Damage: Aerosol systems generally leave little to no residue, minimizing cleanup and damage to sensitive equipment.
o Environmental Friendliness: Aerosol agents are environmentally friendly, with no ozone depletion or global warming potential.
o Versatile Applications: Aerosol systems can be used in various locations, including Transformer rooms, Machine control Room, data centers, battery energy storage systems, and other areas where water damage is undesirable.
Type of Aerosol:
Electrically Operated | Electrical & Thermal Activation | Thermal Activation
GLYPTIC Aerosol Canister comes with Electrical & Thermal Activation by-default with Potential Free contact Feedback. Fire Detection System ( Spot type Smoke & Heat Detector, LHSD, DTS, Beam Detection etc. Directly connected to Aerosol Canister in case of multiple Canister they are getting connected in loop activates through commands from Fire Alarm detection with sequential activation logic.
Design Considerations:
Different brands have their own calculation as per agent contains however GLYPTIC AEROSOL consider as below:
M = Da x Fa x V
M is Total Mass of Agent required for Total Flooding – Kg
Da is Design Application Density (Kg per Meter Cube) – Kg/M3
Fa is Additional Density Factor Where 1.0<500m3, 1.1<1000m3 & 1.2 or more >1000m3.
V is Total volume to be protected (considered zero leakage of the room)
Available Size for GLYPTIC AEROSOL (widest Range): Starts from 30gm, 60gm, 100gm, 200gm, 300gm, 500gm, 750gm, 1.0Kg, 2.0Kg, 2.5Kg, 2.0Kg, 3.5Kg, 4.0Kg, 5.0Kg, 5.7Kg – For wall mount with fittings & fixtures.
And 7.0Kg, 8.0Kg & 10.0Kg comes for Floor Mount being used for very large facility
Effective of Fire Class A, B, C & E. Prevent reignition if the Door and windows are not open. No/ minimal residue left hence cleaning happens automatically when there is a openings. Post discharge of Aerosol cleaning has to happen after 40 minutes wearing necessary safety precaution like Mask & Goggles etc. |